Page 108
... permitted only where it is found necessary to meet condi- tions of installation . This substandard pitch range shall be considered as a critical range to be avoided , if possible . ( 3 ) Scope of coverage in this section . This section ...
... permitted only where it is found necessary to meet condi- tions of installation . This substandard pitch range shall be considered as a critical range to be avoided , if possible . ( 3 ) Scope of coverage in this section . This section ...
Page 109
... permit the raising or lowering of the platform to desired working positions . ( 19 ) Maximum intended load . The total of all loads including the working load , the weight of the scaffold , and such other loads as may be reasonably ...
... permit the raising or lowering of the platform to desired working positions . ( 19 ) Maximum intended load . The total of all loads including the working load , the weight of the scaffold , and such other loads as may be reasonably ...
Page 109
... permitted except for special limited usage and secondary access situations where it is not practi- cal to provide a conventional stairway . Winding stairways may be installed on tanks and similar round structures where the diameter of ...
... permitted except for special limited usage and secondary access situations where it is not practi- cal to provide a conventional stairway . Winding stairways may be installed on tanks and similar round structures where the diameter of ...
Page 109
... permitted only where it is found necessary to meet condi- tions of installation . This substandard pitch range shall be considered as a critical range to be avoided , if possible . ( 3 ) Scope of coverage in this section . This section ...
... permitted only where it is found necessary to meet condi- tions of installation . This substandard pitch range shall be considered as a critical range to be avoided , if possible . ( 3 ) Scope of coverage in this section . This section ...
Page 113
... permitted in tables D- 13 , 14 , and 15 , of this section . Draw- ings and specifications of all tube and coupler scaffolds above the limitations in tables D - 13 , 14 , and 15 of this sec- tion shall be designed by a registered ...
... permitted in tables D- 13 , 14 , and 15 , of this section . Draw- ings and specifications of all tube and coupler scaffolds above the limitations in tables D - 13 , 14 , and 15 of this sec- tion shall be designed by a registered ...
Other editions - View all
Common terms and phrases
A-weighted accordance American National Standard ammonium nitrate ANSI apply approved Assistant Secretary audiogram belt breathing gas building cable capacity circuit Class combustible comply Compressed Gas Association conductors connections construction container crane cylinders decibels designed diameter discharge dive electric employees enclosure equipment exceed explosives exposure extinguishers feet flammable floor fusible plug graph ground grounding conductor guard hazard hoisting horizontal hose inches inspection installed ladder least less liquefied petroleum gas liquid load located machine material maximum means ment metal minimum NFPA operation OSHA paragraph piping platform ployees portable pressure prevent rail rated relief valve requirements rope safe Safety and Health safety relief devices scaffold side slings sound level sound level meter specific spray storage Subpart switch Table tank tion trucks vapor vehicle vent ventilation vertical vided volts wall welding wheels wire wire rope
Popular passages
Page 27 - Each employer — ( 1 ) shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees; (2) shall comply with occupational safety and health standards promulgated under this Act.
Page 11 - ... to the extent feasible, on the basis of the best available evidence, that no employee will suffer material impairment of health or functional capacity even if such employee has regular exposure to the hazard dealt with by such standard for the period of his working life.
Page 28 - ... any factory, plant, establishment, construction site, or other area, workplace or environment where work is performed by an employee of an employer; and (2) to inspect and investigate during regular working hours and at other reasonable times, and within reasonable limits and in a reasonable manner, any such place of employment and all pertinent conditions, structures, machines, apparatus, devices, equipment, and materials therein...
Page 625 - Class I locations. Class I locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitible mixtures.
Page 31 - All information reported to or otherwise obtained by the Secretary or his representative pursuant to this subsection which information contains or relates to a trade secret or other matter referred to in section 1905 of title 18 of the United States Code, shall be considered confidential for the purpose of that section, except that such information may be disclosed to other officers or employees concerned with carrying out this Act or when relevant in any proceeding under this Act. Nothing in this...
Page 52 - Every party shall have the right to present his case or defense by oral or documentary evidence, to submit rebuttal evidence, and to conduct such cross-examination as may be required for a full and true disclosure of the facts.
Page 52 - Irrelevant, or unduly repetitious, or which is not of the sort upon which responsIble persons are accustomed to rely. (2) Objections. If a party objects to the admission or rejection of any evidence or to the limitation of the scope of any examination or cross-examination...
Page 32 - ... and a copy shall be provided the employer or his agent no later than at the time of inspection, except that, upon the request of the person giving such notice, his name and the names of individual employees referred to therein shall not appear in such copy or on any record published, released, or made available pursuant to subsection (g) of this section.
Page 389 - Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.
Page 628 - Ground. A conducting connection, whether intentional or accidental, between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth.