FIGURE 14

BONDING AND GROUNDING OF LARGE CABLES INSIDE PEDESTALS USING MULTIPLE SHIELD BOND CONNECTORS AND HARNESS WRES

[graphic][subsumed][subsumed][subsumed][merged small][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed]

Note: The maximum number of harness wires that can be installed on each stud of the ground bracket shall be in accordance with the manufacturer's instructions.

FIGURE 15

ALTERNATIVE METHOD OF BONDING AND GROUNDING LARGE CABLES IN PEDESTALS USING MULTIPLE SHIELD BOND CONNECTORS AND 6 AWG WRE BRAID

[graphic][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][ocr errors][subsumed][merged small][merged small][subsumed][subsumed][subsumed]

FIGURE 16

ALTERNATIVE METHOD OF BONDING AND GROUNDING SEVERAL
CABLES IN PEDESTALS USING SHIELD BOND CONNECTORS
AND 6 AWG WIRE BRAID LOOP

[graphic][subsumed][subsumed][merged small][merged small][merged small][subsumed][subsumed][subsumed][merged small]

(3) Buried service wire shield bond connections. Buried service wire shields shall be connected to the pedestal bonding and grounding system. Typical buried service wire installations are shown in Figures 17 and 18. In addition to the methods referenced in Figures 17 and 18, the shields of buried service wires may also be connected to the pedestal bonding and grounding system

using buried service wire bonding harnesses listed on Page 3.3.1, Item "gs-b," of RUS Bulletin 17551-100. RUS Bulletin 17551-100 may be purchased from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. When those harnesses are used they shall be installed in accordance with the manufacturer's instructions. Figures 17 and 18 are as follows: