The Code of Federal Regulations of the United States of AmericaU.S. Government Printing Office, 1996 - Administrative law The Code of Federal Regulations is the codification of the general and permanent rules published in the Federal Register by the executive departments and agencies of the Federal Government. |
From inside the book
Results 1-5 of 48
Page 24
... strength , general corrosion that has reduced the wall thickness to less than that re- quired for the maximum allowable op- erating pressure , and localized corro- sion pitting to a degree where leakage might result . ( 2 ) Unintended ...
... strength , general corrosion that has reduced the wall thickness to less than that re- quired for the maximum allowable op- erating pressure , and localized corro- sion pitting to a degree where leakage might result . ( 2 ) Unintended ...
Page 25
... strength . ( 5 ) Any malfunction or operating error that causes the pressure of a pipeline or LNG facility that contains or processes gas or LNG to rise above its maximum allowable operating pres- sure ( or working pressure for LNG fa ...
... strength . ( 5 ) Any malfunction or operating error that causes the pressure of a pipeline or LNG facility that contains or processes gas or LNG to rise above its maximum allowable operating pres- sure ( or working pressure for LNG fa ...
Page 26
... strength ( S ) for steel pipe . 192.109 Nominal wall thickness ( t ) for steel pipe . 192.111 Design factor ( F ) for steel pipe . 192.113 Longitudinal joint factor ( E ) for steel pipe . 192.115 Temperature derating factor ( T ) for ...
... strength ( S ) for steel pipe . 192.109 Nominal wall thickness ( t ) for steel pipe . 192.111 Design factor ( F ) for steel pipe . 192.113 Longitudinal joint factor ( E ) for steel pipe . 192.115 Temperature derating factor ( T ) for ...
Page 28
... Strength test requirements for steel pipeline to operate at a hoop stress of 30 percent or more of SMYS . 192.507 Test requirements for pipelines to operate at a hoop stress less than 30 per- cent of SMYS and at or above 100 p.s.i.g. ...
... Strength test requirements for steel pipeline to operate at a hoop stress of 30 percent or more of SMYS . 192.507 Test requirements for pipelines to operate at a hoop stress less than 30 per- cent of SMYS and at or above 100 p.s.i.g. ...
Page 30
... strength is : minimum ( 1 ) For steel pipe manufactured in ac- cordance with a listed specification , the yield strength specified as a mini- mum in that specification ; or ( 2 ) For steel pipe manufactured in ac- cordance with an ...
... strength is : minimum ( 1 ) For steel pipe manufactured in ac- cordance with a listed specification , the yield strength specified as a mini- mum in that specification ; or ( 2 ) For steel pipe manufactured in ac- cordance with an ...
Other editions - View all
Common terms and phrases
accordance agency alcohol test allowable operating pressure amended by Amdt ANSI/NFPA Appendix applicable ASME/ANSI Associate Administrator ASTM carbon dioxide cathodic protection cluding component compressor station corrosion covered employee damage design pressure determined devices drug test ductile iron emergency equipment erator Federal Acquisition Regulation Federal Register FERC fire flammable hazardous liquid hoop stress inches inspection installed internal joint July July 27 June leak least liquid or carbon LNG facility LNG plant LNG storage tank located material maximum allowable operating means ment minimum miter joint National nondestructively tested Office offshore percent person personnel petition pipeline facilities pipeline safety pipeline system plastic pipe procedures prohibited drug quired records repair response plan response zone revised River RSPA segment of pipeline service line SMYS Specification Standard steel pipe subpart tank truck temperature tion transmission line valve vapor wall thickness weld yield strength