The Code of Federal Regulations of the United States of AmericaU.S. Government Printing Office, 1996 - Administrative law The Code of Federal Regulations is the codification of the general and permanent rules published in the Federal Register by the executive departments and agencies of the Federal Government. |
From inside the book
Results 1-5 of 41
Page 29
... inches below the seabed in water less than 15 feet deep , as measured from the mean low water . High - pressure distribution system means a distribution system in which the gas pressure in the main is higher than the pressure provided ...
... inches below the seabed in water less than 15 feet deep , as measured from the mean low water . High - pressure distribution system means a distribution system in which the gas pressure in the main is higher than the pressure provided ...
Page 34
... inch gauge . S - Yield strength in pounds per square inch determined 34 § 192.63 49 CFR Ch . I ( 10-1-96 Edition )
... inch gauge . S - Yield strength in pounds per square inch determined 34 § 192.63 49 CFR Ch . I ( 10-1-96 Edition )
Page 35
S - Yield strength in pounds per square inch determined in accordance with § 192.107 . D = Nominal outside diameter of the pipe in inches . t = Nominal wall thickness of the pipe in inches . If this is unknown , it is deter- mined in ...
S - Yield strength in pounds per square inch determined in accordance with § 192.107 . D = Nominal outside diameter of the pipe in inches . t = Nominal wall thickness of the pipe in inches . If this is unknown , it is deter- mined in ...
Page 36
... inches or less .60 If the type of longitudinal joint cannot be determined , the joint factor to be used must not exceed that designated for " Other . " [ Amdt . 192-37 , 46 FR 10159 , Feb. 2 , 1981 , as amended by Amdt . 192-51 , 51 FR ...
... inches or less .60 If the type of longitudinal joint cannot be determined , the joint factor to be used must not exceed that designated for " Other . " [ Amdt . 192-37 , 46 FR 10159 , Feb. 2 , 1981 , as amended by Amdt . 192-51 , 51 FR ...
Page 37
... inches and must be hard drawn . ( b ) Copper pipe used in service lines must have wall thickness not less than that indicated in the following table : Standard size ( inch ) Wall thickness ( inch ) Nominal O.D. ( inch ) Nominal ...
... inches and must be hard drawn . ( b ) Copper pipe used in service lines must have wall thickness not less than that indicated in the following table : Standard size ( inch ) Wall thickness ( inch ) Nominal O.D. ( inch ) Nominal ...
Other editions - View all
Common terms and phrases
accordance agency alcohol test allowable operating pressure amended by Amdt ANSI/NFPA Appendix applicable ASME/ANSI Associate Administrator ASTM carbon dioxide cathodic protection cluding component compressor station corrosion covered employee damage design pressure determined devices drug test ductile iron emergency equipment erator Federal Acquisition Regulation Federal Register FERC fire flammable hazardous liquid hoop stress inches inspection installed internal joint July July 27 June leak least liquid or carbon LNG facility LNG plant LNG storage tank located material maximum allowable operating means ment minimum miter joint National nondestructively tested Office offshore percent person personnel petition pipeline facilities pipeline safety pipeline system plastic pipe procedures prohibited drug quired records repair response plan response zone revised River RSPA segment of pipeline service line SMYS Specification Standard steel pipe subpart tank truck temperature tion transmission line valve vapor wall thickness weld yield strength