Page 19
... microcurie ( uc ) equals 0.000001 curie . ( 6 ) Department shall mean the State Department of Health and shall include its duly authorized representatives . ( 7 ) Diagnostic - type protective tube housing shall mean X - ray tube housing ...
... microcurie ( uc ) equals 0.000001 curie . ( 6 ) Department shall mean the State Department of Health and shall include its duly authorized representatives . ( 7 ) Diagnostic - type protective tube housing shall mean X - ray tube housing ...
Page 23
... microcurie / gram ) . ( k ) Radiation equipment that cannot by reason of its design emit radiation at a level which , when measured two inches from the surface of such radiation equip- ment with all external shielding removed , would ...
... microcurie / gram ) . ( k ) Radiation equipment that cannot by reason of its design emit radiation at a level which , when measured two inches from the surface of such radiation equip- ment with all external shielding removed , would ...
Page 28
... microcurie of alpha , 0.05 microcurie of beta , or 0.1 mr / hr [ milliroentgens per hour ] of gamma contamination on the source . Detection of a leak in any sealed source shall result in immediate suspension in the use of such source ...
... microcurie of alpha , 0.05 microcurie of beta , or 0.1 mr / hr [ milliroentgens per hour ] of gamma contamination on the source . Detection of a leak in any sealed source shall result in immediate suspension in the use of such source ...
Page 42
... microcuries of Polonium 210 ; ( ii ) any spark gap or electronic tube containing byproduct material consisting of a total quantity of not more than five microcuries of Cesium 137 , Nickel 63 , or Krypton 85 gas , or one microcurie of ...
... microcuries of Polonium 210 ; ( ii ) any spark gap or electronic tube containing byproduct material consisting of a total quantity of not more than five microcuries of Cesium 137 , Nickel 63 , or Krypton 85 gas , or one microcurie of ...
Page 51
... ( microcuries ) - Column No. II As a sealed source ( microcuries ) 1 ¤¤¤8 - õ -- 68 ÷ -õõõ --- öööööö ÷ 6866 --- 8-8-866-866888-8-8 --- 8608-65 , 10 10 10 10 50 10 10 50 10 10 10 50 10 50 10 50 10 50 10 10 250 10 10 10 50 10 10 10 50 10 ...
... ( microcuries ) - Column No. II As a sealed source ( microcuries ) 1 ¤¤¤8 - õ -- 68 ÷ -õõõ --- öööööö ÷ 6866 --- 8-8-866-866888-8-8 --- 8608-65 , 10 10 10 10 50 10 10 50 10 10 10 50 10 50 10 50 10 50 10 10 250 10 10 10 50 10 10 10 50 10 ...
Other editions - View all
Common terms and phrases
13 consecutive weeks agreement material Air Water amendment application Atomic Energy Commission authorized byproduct material Cerium City Health Code Column 1 Column Commissioner controlled area Department of Health Department of Labor Element atomic number Europium external exposure filed July 16 health and safety Historical Note Sec individual individual's ionizing radiation isotope Item label license or permit limit thereof set ment microcuries millirems mixture Natural Background SCHEDULE natural uranium operation paragraph person who possesses personnel monitoring equipment Praseodymium Promethium public health pursuant radiation equipment radiation protection radiation safety officer radiation source radiation symbol radionuclide registration regulations regulatory rems Rhenium Sanitary Code SCHEDULE I SCHEDULE Schedule II SCHEDULE II Element sealed source source material special nuclear material specified Strontium subdivision Technetium Tellurium Terbium Thorium tritium uc/ml United States Atomic Water above Natural whole body X-ray York City York City Department York City Health Yttrium