SUBCHAPTER C-AIR PROGRAMS

PART 50-NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS

Sec.

50.1

Definitions.

[blocks in formation]

50.4 National primary ambient air quality standards for sulfur oxides (sulfur dioxide).

50.5 National secondary ambient air quality standards for sulfur oxides (sulfur dioxide).

50.6 National primary ambient air quality standards for particulate matter. 50.7 National secondary ambient air quality standards for particulate matter. 50.8 National primary and secondary ambient air quality standards for carbon monoxide.

50.9 National primary and secondary ambient air quality standards for ozone. 50.10 National primary and secondary ambient air quality standard for hydrocarbons.

50.11 National primary and secondary ambient air quality standard for nitrogen dioxide.

50.12 National primary and secondary ambient air quality standards for lead. APPENDIX A-REFERENCE METHOD FOR THE DETERMINATION OF SULFUR DIOXIDE IN THE ATMOSPHERE (PARAROSANILINE METHOD)

APPENDIX B-REFERENCE METHOD FOR THE DETERMINATION OF SUSPENDED PARTICULATES IN THE ATMOSPHERE (HIGH VOLUME METHOD)

APPENDIX C-MEASUREMENT PRINCIPLE AND

CALIBRATION PROCEDURE FOR THE CONTINUOUS MEASUREMENT OF CARBON MONOXIDE IN THE ATMOSPHERE (NON-DISPERSIVE INFRARED SPECTOMETRY) APPENDIX D-MEASUREMENT PRINCIPLE AND CALIBRATION PROCEDURE FOR THE MEASUREMENT OF OZONE IN THE ATMOSPHERE APPENDIX E-REFERENCE METHOD FOR DETERMINATION OF HYDROCARBONS CORRECTED FOR METHANE APPENDIX F-MEASUREMENT PRINCIPLE AND CALIBRATION PROCEDURE FOR THE MEASUREMENT OF NITROGEN DIOXIDE IN THE ATMOSPHERE (GAS PHASE CHEMILUMINESCENCE)

APPENDIX G-REFERENCE METHOD FOR THE DETERMINATION OF LEAD IN SUSPENDED PARTICULATE MATTER COLLECTED FROM AMBIENT AIR

APPENDIX H-INTERPRETATION OF THE NATIONAL AMBIENT AIR QUALITY STANDARDS FOR OZONE

[blocks in formation]

(a) As used in this part, all terms not defined herein shall have the meaning given them by the Act.

(b) "Act" means the Clean Air Act, as amended (42 U.S.C. 1857-18571, as amended by Pub. L. 91-604).

(c) "Agency" means the Environmental Protection Agency.

(d) "Administrator" means the Administrator of the Environmental Protection Agency.

(e) "Ambient air" means that portion of the atmosphere, external to buildings, to which the general public has access.

a

(f) "Reference method" means method of sampling and analyzing the ambient air for an air pollutant that is specified as a reference method in an appendix to this part, or a method that has been designated as a reference method in accordance with Part 53 of this chapter; it does not include a method for which a reference method designation has been cancelled in accordance with § 53.11 or § 53.16 of this chapter.

(g) "Equivalent method" means a method of sampling and analyzing the ambient air for an air pollutant that has been designated as an equivalent method in accordance with Part 53 of this chapter; it does not include a method for which an equivalent method designation has been cancelled in accordance with § 53.11 or § 53.16 of this chapter.

[36 FR 22384, Nov. 25, 1971, as amended at 41 FR 11253, Mar. 17, 1976]

§ 50.2 Scope.

(a) National primary and secondary ambient air quality standards under section 109 of the Act are set forth in this part.

(b) National primary ambient air quality standards define levels of air quality which the Administrator judges are necessary, with an adequate

margin of safety, to protect the public health. National secondary ambient air quality standards define levels of air quality which the Administrator judges necessary to protect the public welfare from any known or anticipated adverse effects of a pollutant. Such standards are subject to revision, and additional primary and secondary standards may be promulgated as the Administrator deems necessary to protect the public health and welfare.

(c) The promulgation of national primary and secondary ambient air quality standards shall not be considered in any manner to allow significant deterioration of existing air quality in any portion of any State.

(d) The proposal, promulgation, or revision of national primary and secondary ambient air quality standards shall not prohibit any State from establishing ambient air quality standards for that State or any portion thereof which are more stringent than the national standards.

§ 50.3 Reference conditions.

All measurements of air quality are corrected to a reference temperature of 25° C. and to a reference pressure of 760 millimeters of mercury (1,013.2 millibars).

§ 50.4 National primary ambient air quality standards for sulfur oxides (sulfur dioxide).

The national primary ambient air quality standards for sulfur oxides measured as sulfur dioxide by the reference method described in Appendix A to this part, or by an equivalent method, are:

(a) 80 micrograms per cubic meter (0.03 p.p.m.)—annual arithmetic mean. (b) 365 micrograms per cubic meter (0.14 p.p.m.)—Maximum 24-hour concentration not to be exceeded more than once per year.

§ 50.5 National secondary ambient air quality standards for sulfur oxides (sulfur dioxide).

The national secondary ambient air quality standard for sulfur oxide measured as sulfur dioxide by the reference method described in Appendix A to this part, or by any equivalent method is 1,300 micrograms per cubic

meter (0.5 p.p.m.) maximum 3-hour concentration not to be exceeded more than once per year.

[38 FR 25681, Sept. 14, 1973]

§ 50.6 National primary ambient air quality standards for particulate matter.

The national primary ambient air quality standards for particulate matter, measured by the reference method described in Appendix B to this part, or by an equivalent method,

are:

(a) 75 micrograms per cubic meterannual geometric mean.

(b) 260 micrograms per cubic meter-maximum 24-hour concentration not to be exceeded more than once per year.

§ 50.7 National secondary ambient air quality standards for particulate matter.

The national secondary ambient air quality standards for particulate matter, measured by the reference method described in Appendix B to this part, or by an equivalent method,

are:

(a) 60 micrograms per cubic meterannual geometric mean, as a guide to be used in assessing implementation plans to achieve the 24-hour standard.

(b) 150 micrograms per cubic

meter-maximum 24-hour concentration not to be exceeded more than once per year.

§ 50.8 National primary and secondary ambient air quality standards for carbon monoxide.

The national primary and secondary ambient air quality standards for carbon monoxide, measured by a reference method based on Appendix C to this part and designated in accordance with Part 53 of this chapter, or by an equivalent method, are:

(a) 10 milligrams per cubic meter (9 p.p.m.)-maximum 8-hour concentration not to be exceeded more than once per year.

(b) 40 milligrams per cubic meter (35 p.p.m.)-maximum 1-hour concentration not to be exceeded more than once per year.

[36 FR 22384, Nov. 25, 1971, as amended at 40 FR 7043, Feb. 18, 1975]

§ 50.9 National primary and secondary ambient air quality standards for

ozone.

(a) The level of the national primary and secondary ambient air quality standards for ozone measured by a reference method based on Appendix D to this part and designated in accordance with Part 53 of this chapter, is 0.12 part per million (235 μg/m3). The standard is attained when the expected number of days per calendar year with maximum hourly average concentrations above 0.12 part per million (235 μg/m3) is equal to or less than 1, as determined by Appendix H.

(Secs. 109 and 301 of the Clean Air Act, as amended (42 U.S.C. 7409, 7601)) [44 FR 8220, Feb. 8, 1979]

§ 50.10 National primary and secondary ambient air quality standard for hydrocarbons.

The hydrocarbons standard is for use as a guide in devising implementation plans to achieve oxidant standards. The national primary and secondary ambient air quality standard for hydrocarbons, measured and corrected for methane by the reference method described in Appendix E to this part, or by an equivalent method, is: 160 micrograms per cubic meter (0.24 p.p.m.)-maximum 3-hour concentration (6 to 9 a.m.) not to be exceeded more than once per year.

[blocks in formation]

by an equivalent method, are: 1.5 micrograms per cubic meter, maximum arithmetic mean averaged over a calendar quarter.

(Secs. 109, 301(a) Clean Air Act as amended (42 U.S.C. 7409, 7601(a))) [43 FR 46258, Oct. 5, 1978]

APPENDIX A-REFERENCE METHOD FOR THE DETERMINATION OF SULFUR DIOXIDE IN THE ATMOSPHERE (PARAROSANILINE METHOD)

1. Principle and Applicability. 1.1 Sulfur dioxide is absorbed from air in a solution of potassium tetrachloromercurate (TCM). A dichlorosulfitomercurate complex, which resists oxidation by the oxygen in the air, is formed (1, 2). Once formed, this complex is stable to strong oxidants (e.g., ozone, oxides of nitrogen). The complex is reacted with pararosaniline and formaldehyde to form intensely colored pararosaniline methyl sulfonic acid (3). The absorbance of the solution is measured spectrophotometrically.

1.2 The method is applicable to the measurement of sulfur dioxide in ambient air using sampling periods up to 24 hours.

2. Range and Sensitivity. 2.1 Concentrations of sulfur dioxide in the range of 25 to 1,050 μg/m.3 (0.01 to 0.40 p.p.m.) can be measured under the conditions given. One can measure concentrations below 25 μg./ m. by sampling larger volumes of air, but only if the absorption efficiency of the particular system is first determined. Higher concentrations can be analyzed by using smaller gas samples, a larger collection volume, or a suitable aliquot of the collected sample. Beer's Law is followed through the working range from 0.03 to 1.0 absorbance units (0.8 to 27 μg. of sulfite ion in 25 ml. final solution computed as SO2).

2.2 The lower limit of detection of sulfur dioxide in 10 ml. TCM is 0.75 μg. (based on twice the standard deviation) representing a concentration of 25 μg./m 'SO, (0.01 p.p.m.) in an air sample of 30 liters.

3. Interferences. 3.1 The effects of the principal known interferences have been minimized or eliminated. Interferences by oxides of nitrogen are eliminated by sulfamic acid (4, 5), ozone by time-delay (6), and heavy metals by EDTA (ethylene-diaminetetraacetic acid, disodium salt) and phosphoric acid (4, 6). At least 60 μg. Fe (III), 10 ug. Mn (II), and 10 μg. Cr (III) in 10 ml. absorbing reagent can be tolerated in the procedure. No significant interference was found with 10 μg. Cu (II) and 22 μg. V (V). 4. Precision, Accuracy, and Stability. 4.1 Relative standard deviation at the 95 percent confidence level is 4.6 percent for the

analytical procedure using standard samples. (5)

4.2 After sample collection the solutions are relatively stable. At 22 C. losses of sulfur dioxide occur at the rate of 1 percent per day. When samples are stored at 5° C. for 30 days, no detectable losses of sulfur dioxide occur. The presence of EDTA enhances the stability of SO, in solution, and the rate of decay is independent of the concentration of SO2. (7)

5. Apparatus.

5.1 Sampling.

5.1.1 Absorber. Absorbers normally used in air pollution sampling are acceptable for concentrations above 25 μg./m.3 (0.01 p.p.m.). An all-glass midget impinger, as shown in Figure A1, is recommended for 30minute and 1-hour samples.

For 24-hour sampling, assemble an absorber from the following parts:

Polypropylene 2-port tube closures, special manufacture (available from Bel-Art Products, Pequannock, N.J.).

Glass impingers, 6 mm. tubing, 6 inches long, one end drawn to small diameter such that No. 79 jewelers drill will pass through, but No. 78 jewelers drill will not. (Other end fire polished.)

Polypropylene tubes, 164 by 32 mm. (Nalgene or equal).

5.1.2 Pump. Capable of maintaining an air pressure differential greater than 0.7 atmosphere at the desired flow rate.

5.1.3 Air Flowmeter or Critical Orifice. A calibrated rotameter or critical orifice capable of measuring air flow within ±2 percent. For 30-minute sampling, a 22-gauge hypodermic needle 1 inch long may be used as a critical orifice to give a flow of about 1 liter/ minute. For 1-hour sampling, a 23-gauge hypodermic needle five-eights of an inch long may be used as a critical orifice to give a flow of about 0.5 liter/minute. For 24-hour sampling, a 27-gauge hypodermic needle three-eighths of an inch long may be used to give a flow of about 0.2 liter/minute. Use a membrane filter to protect the needle (Figure Ala).

[blocks in formation]

solve 10.86 g. mercuric chloride, 0.066 g. EDTA (ethylenediaminetetraacetic acid, disodium salt), and 6.0 g. potassium chloride in water and bring to mark in a 1.000-ml. volumetric flask. (Caution: Highly poisonous. If spilled on skin, flush off with water immediately). The pH of this reagent should be approximately 4.0, but it has been shown that there is no appreciable difference in collection efficiency over the range of pH 5 to pH 3.(7). The absorbing reagent is normally stable for 6 months. If a precipitate forms, discard the reagent.

6.2 Analysis.

6.2.1 Sulfamic Acid (0.6 percent). Dissolve 0.6 g. sulfamic acid in 100 ml. distilled water. Prepare fresh daily.

6.2.2 Formaldehyde (0.2 percent). Dilute 5 ml. formaldehyde solution (36-38 percent) to 1,000 ml. with distilled water. Prepare daily.

6.2.3 Stock Iodine Solution (0.1 N). Place 12.7 g. iodine in a 250-ml. beaker; add 40 g. potassium iodide and 25 ml. water. Stir until all is dissolved, then dilute to 1,000 ml. with distilled water.

6.2.4 Iodine Solution (0.01 N). Prepare approximately 0.01 N iodine solution by diluting 50 ml. of stock solution to 500 ml. with distilled water.

6.2.5 Starch Indicator Solution. Triturate 0.4 g. soluble starch and 0.002 g. mercuric iodide (preservative) with a little water, and add the paste slowly to 200 ml. boiling water. Continue boiling until the solution is clear; cool, and transfer to a glassstoppered bottle.

6.2.6 Stock Sodium Thiosulfate Solution (0.1 N). Prepare a stock solution by dissolving 25 g. sodium thiosulfate (Na,S2O,-5H2O) in 1,000 ml freshly boiled, cooled, distilled water and add 0.1 g. sodium carbonate to the solution. Allow the solution to stand 1 day before standardizing. To standardize, accurately weigh, to the nearest 0.1 mg., 1.5 g. primary standard potassium iodate dried at 180° C. and dilute to volume in a 500-ml. volumetric flask. To a 500-ml. iodine flask. pipet 50 ml. of iodate solution. Add 2 g. potassium iodide and 10 ml. of 1 N hydrochloric acid. Stopper the flask. After 5 minutes. titrate with stock thiosulfate solution to a pale yellow. Add 5 ml. starch indicator solution and continue the titration until the blue color disappears. Calculate the normality of the stock solution:

N=(W/M)× 2.80

N = Normality of stock thiosulfate solution.
M = Volume of thiosulfate required, ml.
W = Weight of potassium iodate, grams.

2.80=[10 conversion of g. to mg.) x 0.1 (fraction iodate used)]/35.67 (equivalent weight of potassium iodate)

6.2.7 Sodium Thiosulfate Titrant (0.01 N). Dilute 100 ml. of the stock thiosulfate solution to 1,000 ml. with freshly boiled distilled water.

Normality=Normality of stock
solution X 0.100.

6.2.8 Standardized Sulfite Solution for Preparation of Working Sulfite-TCM Solution. Dissolve 0.3 g. sodium metabisulfite (Na2S2O1) or 0.40 g. sodium sulfite (Na2SO1) in 500 ml. of recently boiled, cooled, distilled water. (Sulfite solution is unstable; it is therefore important to use water of the highest purity to minimize this instability.) This solution contains the equivalent of 320 to 400 μg/ml. of SO2. The actual concentration of the solution is determined by adding excess iodine and back-titrating with standard sodium thiosulfate solution. To back-titrate, pipet 50 ml. of the 0.01 N iodine into each of two 500-ml. iodine flasks (A and B). To flask A (blank) add 25 ml. distilled water, and to flask B (sample) pipet 25 ml. sulfite solution. Stopper the flasks and allow to react for 5 minutes. Prepare the working sulfite-TCM Solution (6.2.9) at the same time iodine solution is added to the flasks. By means of a buret containing standardized 0.01 N thiosulfate, titrate each flask in turn to a pale yellow. Then add 5 ml. starch solution and continue the titration until the blue color disappears.

[blocks in formation]

μgSO2/ml.=((A−B) (N) (32,000)/25) (×0.02) A = Volume thiosulfate for blank, ml. B=Volume thiosulfate for sample, ml. N = Normality of thiosulfate titrant. 32,000 Milliequivalent wt. of SO2, μg. 25 Volume standard sulfite solution, ml. 0.02 Dilution factor.

This solution is stable for 30 days if kept at 5° C. (refrigerator). If not kept at 5° C., prepare daily.

6.2.10 Purified Pararosaniline Stock Solution (0.2 percent nominal).

6.2.10.1 Dye Specifications. The pararosaniline dye must meet the following performance specifications: (1) The dye must have a wavelength of maximum absorbance at 540 nm. when assayed in a buffered solution of 0.1 M sodium acetate-acetic acid; (2) the absorbance of the reagent blank, which is temperature-sensitive (0.015 absorbance unit/°C), should not exceed 0.170 absorbance unit at 22° C. with a 1-cm. optical

path length, when the blank is prepared according to the prescribed analytical procedure and to the specified concentration of the dye; (3) the calibration curve (Section 8.2.1) should have a slope of 0.030±0.002 absorbance units/μg. SO2 at this path length when the dye is pure and the sulfite solution is properly standardized.

6.2.10.2 Preparation of Stock Solution. A specially purified (99-100 percent pure) solution of pararosaniline, which meets the above specifications, is commercially available in the required 0.20 percent concentration (Harleco'). Alternatively, the dye may be purified, a stock solution prepared and then assayed according to the procedure of Scaringelli, et al. (4)

6.2.11 Pararosaniline Reagent. To a 250ml. volumetric flask, add 20 ml. stock pararosaniline solution. Add an additional 0.2 ml. stock solution for each percent the stock assays below 100 percent. Then add 25 ml. 3 M phosphoric acid and dilute to volume with distilled water. This reagent is stable for at least 9 months.

7. Procedure.

7.1 Sampling. Procedures are described for short-term (30 minutes and 1 hour) and for long-term (24 hours) sampling. One can select different combinations of sampling rate and time to meet special needs. Sample volumes should be adjusted, so that linearity is maintained between absorbance and concentration over the dynamic range.

7.1.1 30-Minute and 1-Hour Samplings. Insert a midget impinger into the sampling system, Figure A1. Add 10 ml. TCM solution to the impinger. Collect sample at 1 liter/ minute for 30 minutes, or at 0.5 liter/minute for 1 hour, using either a rotameter, as shown in Figure A1, or a critical orifice, as shown in Figure Ala, to control flow. Shield the absorbing reagent from direct sunlight during and after sampling by covering the impinger with aluminum foil, to prevent deterioration. Determine the volume of air sampled by multiplying the flow rate by the time in minutes and record the atmospheric pressure and temperature. Remove and stopper the impinger. If the sample must be stored for more than a day before analysis, keep it at 5° C. in a refrigerator (see 4.2).

7.1.2 24-Hour Sampling. Place 50 ml. TCM solution in a large absorber and collect the sample at 0.2 liter/minute for 24 hours from midnight to midnight. Make sure no entrainment of solution results with the impinger. During collection and storage protect from direct sunlight. Determine the total air volume by multiplying the air flow rate by the time in minutes. The correction of 24-hour measurements for temperature