Hidden fields
Books Books
" If the depth of such a well exceeds half the height of the double bottom, h, shall be taken equal to the double bottom height minus the well height. Piping serving such wells if installed within the double bottom shall be fitted with valves or other closing... "
Ports and Waterways: Hearings Before the Committee on Commerce, United ... - Page 281
by United States. Congress. Senate. Committee on Commerce - 1976 - 437 pages
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 1996 - 788 pages
...enters the tank. (e) If piping that serves suction wells is installed within a double bottom, that piping must be: (1) Fitted with valves located at...installed as high from the bottom shell as possible. [CGD 74-32, 40 FR 48283, Oct. 14, 1975, as amended by CGD 75-240, 41 FR 54180, Dec. 13, 1976; CGD 7&-088b....
Full view - About this book

The Code of Federal Regulations of the United States of America

Administrative law - 2000 - 868 pages
...enters the tank. (e) If piping that serves suction wells is installed within a double bottom, that piping must be: (1) Fitted with valves located at...installed as high from the bottom shell as possible. [COD 74-32. 40 FR 48283. Oct. 14, 1975, as amended by CGD 75-240, 41 FR 54180, Dec. 13, 1976; CGD 76-088b,...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 2000 - 868 pages
...piping that serves suction wells is installed within a double bottom, that piping must be: (1) Pitted with valves located at the point of connection to...installed as high from the bottom shell as possible. [COD 74-32, 40 FR 48283, Oct. 14, 1975, as amended by CGD 75-240, 41 FR 54180. Dec. 13, 1976; CGD 7S-088b,...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 2001 - 894 pages
...spaces must be placed as far from the outer shell as is practicable and must be fitted with valves at the point of connection to the tank served, to...oil outflow in the event of damage to the piping. Such valves must be closed whenever the vessel is underway with any oil in tanks served by the associated...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 1999 - 880 pages
...spaces must be placed as far from the outer shell as is practicable and must be fitted with valves at the point of connection to the tank served, to...oil outflow in the event of damage to the piping. Such valves must be closed whenever the vessel is underway with any oil in tanks served by the associated...
Full view - About this book

The Code of Federal Regulations of the United States of America

Administrative law - 1983 - 976 pages
...wells if Installed within the double bottom shall be fitted with valves or other closing arrangements located at the point of connection to the tank served to prevent oil outflow in the event of damage of the piping during stranding. Such piping shall be installed as high from the bottom shell as possible....
Full view - About this book

Rules and Regulations for Tank Vessels (title 46, C. F. R., Parts 30 to 39 ...

United States. Coast Guard - Tankers - 1977 - 1570 pages
...the branch opens. (e) If piping that serves suction wells Is installed within a double bottom, that oU outflow in the event of damage to the piping; and (2) Designed to be installed as high from the...
Full view - About this book

Port and Harbor Safety: Hearings, Ninety-second Congress, First Session ...

United States. Congress. House. Committee on Merchant Marine and Fisheries. Subcommittee on Coast Guard, Coast and Geodetic Survey, and Navigation - Harbors - 1971 - 416 pages
...wells if installed within the double bottom should be fitted with valves or other closing arrangements located at the point of connection to the tank served to prevent oil outflow in the event of damage of the piping during stranding. Such piping chould be installed as high from the bottom shell as possible....
Full view - About this book

Port and Harbor Safety: Hearings Before the Subcommittee on Coast Guard ...

United States. Congress. House. Merchant Marine and Fisheries - 1971 - 426 pages
...wells if installed within the double bottom should be fitted with valves or other closing arrangements located at the point of connection to the tank served to prevent oil outflow in the event of damage of the piping during stranding. Such piping ehould be installed as high from the bottom shell as possible....
Full view - About this book

International Compensation Fund for Oil Pollution Damage, Hearings Before ...

United States. Congress. Senate. Foreign Relations - 1973 - 214 pages
...wells if installed within the double bottom shall be fitted with valves or other closing arrangements located at the point of connection to the tank served to prevent oil outflow in he event of damage of thd piping during stranding. Such piping shall 0 installed as high from the bottom...
Full view - About this book




  1. My library
  2. Help
  3. Advanced Book Search
  4. Download EPUB
  5. Download PDF