[blocks in formation]

"On deck in open."

"On deck under cover."

Required conditions for transportation-Continued

"Tween decks readily accessible." Outside containers:

Steel barrels or drums

(DOT-5, 5A, 5B, 5C, 5G) not over
110 gal. cap.

(DOT-5M) not over 55 gal. cap.
(DOT-170, 17E, 17H) STC not
over 55 gal. cap

(DOT-17H, 37A) WIC of glass,

not over 9 pints capacity each. (DOT-17H. 37A) WIC of glass,

not over 9 pints capacity each. (DOT-37P) NRC, not over 5 gal.

cap.

Cylindrical steel overpacks:

(DOT-6D) WIC DOT-28. not over 55 gal. cap.

(DOT-6D, 37M (NRC)), WIC DOT-2SL, not over 55 gal. cap. Aluminum barrels or drums: (DOT-42B, 42C, not over 110 gal. cap.

(DOT-42H) not over 55 gal. cap. Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal. сар.

(DOT-11A, 11B) WIC not over 16 gal. cap.

Wooden boxes,WIC (DOT-15A, 15B, 150, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIC:

(DOT-12A, 12B) not over 65 lb. gr. wt.

(DOT-12P) WIC DOT-2U, not over 5 gal. cap. Fiber or plywood drums (DOT-21C, 22A, 22B) WIC not over 1 gal. сар.

Fiber drum (DOT-21P) WIC DOT-28, DOT-2SL, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acetylene.

Ferry vessel, passenger or vehicle

Ferry stowage (AA).. Outside containers: Steel barrels or drums: (DOT-5, 5A, 5B. 5C, 5G) not over 110 gal. cap. (DOT-5M) not over 55 gal. cap. (DOT-170. 17E, 17H) ŠTO not over 55 gal. cap. (DOT-17H, 37A) WIC of glass,

not over 9 pints capacity each. (DOT-37P) NRC, not over 5 gal.

cap.

Cylindrical steel overpacks: (DOT-6D) WIC DOT-28, not over 55 gal. cap.

(DOT-6D, 37M (NRC,)) WIC DOT 28L, not over 55 gal, cap. Aluminum barrels or drums: (DOT-42B, 42C) not over 110 gal. cap.

(DOT-42H) not over 55 gal.cap. Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal. cap.

(DOT-11A. 11B) WIC not over 16 gal. cap.

Wooden boxes, WIC (DOT-15A, 15B, 150, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIC: (DOT-12A, 12B) not over 65 lb. gr. wt.

(DOT-12E) WIMO not over 110 lb. gr. wt.

(DOT-12P) WIC DOT-2U, not over 5 gal. cap.

Fiber or plywood drums (DOT210, 22A, 22B) WIC not over 1 gal. cap.

Fiber drum (DOT-21P) WIC DOT-28, DOT-28L, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acetylene.

R. R. car ferry, passenger or vehicle

Ferry stowage (BB).
Outside containers:

Steel barrels or drums:

(DOT-5, 5A, 5B, 50, 5G) not
over 110 gal. cap.

(DOT-5M) not over 55 gal. cap.
(DOT-17C, 17E. 17H) STC pot
over 55 gal. cap.

(DOT-17H, 37A) WIC of glass, not over 9 pints capacity each. (DOT-37P) NRC, not over 5 gal. cap. Cylindrical steel overpacks: (DOT-6D) WIC DOT-28, not over 55 gal. cap.

(DOT-6D, 37M(NRC)), WIC DOT 2SL, not over 55 gal, cap. Aluminum barrels or drums: (DOT-42B, 42C) not over 110 gal. cap.

(DOT-42H) not over 55 gal. cap. Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal.

cap.

(DOT-11A, 11B) WIO not over 16 gal. cap.

Wooden boxes. WIC (DOT-15A, 15B, 150, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIO:

(DOT-12A, 12B) not over 65 lb. gr. wt.

(DOT-12E) WIMO not over 110 lb. gr. wt.

(DOT-12P) WIC DOT-2U, not over 5 gal. cap.

Fiber or plywood drums (DOT210, 22A, 22B) WIO not over 1 gal. cap. Fiber

drum (DOT-21P) WIO DOT-28, DOT-28L, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acetylene. Authorized only for export shipments:

Steel barrels or drums (DOT17X) 8TC, not over 55 gal. cap. Wooden boxes, WIMO (DOT15X) not over 10 gal. cap.

36-102-70———14

[blocks in formation]

Colorless heavy liquid having a pungent odor. Insoluble in water. Does not evaporate

Red.......

Stowage:

"On deck in open."

[blocks in formation]

"On deck under cover.'

"

"Tween decks readily accessible.' "

"Under deck away from heat." Outside containers:

Steel barrels or drums:

(DOT-5, 5A, 5B, 5C, 5G) not over 110 gal. cap.

(DOT-5M) not over 55 gal. cap.
(DOT-17C. 17E, 17H) STO
not over 55 gal. cap.

(DOT-17H, 37A) WIC of glass,
not over 9 pts. cap. each.
(DOT-37P) NRC, not over 5
gal. cap.

Cylindrical steel overpacks:
(DOT-6D)WIC DOT-28, not
over 55 gal. cap.

(DOT-6D,37M, (NRC)), WIO
DOT 28L, not over 55 gal. cap.
Aluminum barrels or drums
(DOT-42B, 42C) not over 110
gal, cap.

(DOT-42H) not over 55 gal. cap.

Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal. cap.

(DOT-11A,11B) WIC not over 16 gal. cap.

Wooden boxes, WIC (DOT-15A, 15B, 150, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIO:

(DOT-12A, 12B) not over 65 lb. gr. wt.

(DOT-12E) WIMO not over 110 lb. gr. wt.

Fiber or ply wood drums (DOT21C, 22A, 22B) WIC not over 1 gal. cap.

Fiber drum (DOT-21P) WIC DOT-2S, DOT-2SL, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acety. lene.

Authorized for stowage "On

deck in open" only:

Portable tanks (DOT-51) not over 20,000 lb. gr. wt.

Authorized for stowage "On

deck" and "First deck below":

Motor vehicle tank trucks complying with DOT regulations (trallerships

trainships only).

and

Tank cars complying with DOT regulations (trainships only).

Authorized only for export ship

ments:

Steel barrels or drums (DOT17X) STO, not over 55 gal. сар. Wooden boxes, WIMC (DOT15X) not over 10 gal. cap.

Inflammable liquids-Continued

[blocks in formation]

Required conditions for transportation-Continued

"Tween decks readily accessible." Outside containers:

Steel barrels or drums:

(DOT-5, A, 5B, 50, 5G) not
over 110 gal. cap.
(DOT-5M) not over 55 gal. cap.
(DOT-170, 17E, 17H) STC not
over 55 gal. cap.

(DOT-171, 37A) WIC of glass,
not over 9 pints capacity each.
(DOT-37P) NRC, not over 5 gal.

cap.

Cylindrical steel overpacks:

(DOT-6D) WIC DOT-28 not over 55 gal. cap.

(DOT-61, 37M (NRC)), WIC DOT 2SL, not over 55 gal, cap. Aluminum barrels or drums: (DOT-42B, 42C) not over 110 gal. cap.

(DOT-42H) not over 55 gal. cap. Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal. сар.

(DOT-11A, 11B) WIC not over 16 gal. cap.

Wooden boxes, WIO (DOT-15A, 15B, 15C, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIC (DOT-12A, 12B) not over 65 lb. gr. wt. Fiber or plywood drums (DOT210, 22A, 22B) WIC not over 1 gal. cap.

Fiber drum (DOT-21P) WIC DOT28, DOT-28L, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acetylene.

Ferry vessel, passenger or vehicle

Ferry stowage (AA). Outside containers: Steel barrels or drums: (DOT-5, 5A, 5B, 5C, 5G) not over 110 gal. cap. (DOT-5M) not over 55 gal. cap. (DOT-170, 17E, 17H) STO not over 55 gal. cap. (DOT-17H, 37A) WIO of glass, not over 9 pints capacity each. (DOT-37P) NRC, not over 5 gal. cap.

Cylindrical steel overpacks: (DOT-6D) WIC DOT-28, not over 55 gal. cap. (DOT-6D, 37M(NRC)). WIO DOT 281, not over 55 gal, cap. Aluminum barrels or drums: (DOT-42B, 42C) not over 110 gal. cap.

(DOT-42H) not over 55 gal. cap. Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal. cap.

(DOT-11A, 11B) WIC not over

16 gal. cap.

Wooden boxes, WIC (DOT-15A, 15B, 15C, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIC:

(DOT-12A, 12B) not over 65 lb. gr. wt.

(DOT-12E) WIMC not over 110 lb. gr. wt.

Fiber or plywood drums (DOT210, 22A, 22B) WIC not over 1 gal. cap.

Fiber drum (DOT-21P) WIO DOT-28, DOT-28L, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acetylene.

[blocks in formation]

(DOT-42H) not over 55 gal. cap. Wooden barrels or kegs:

(DOT-10A, 10B) not over 50 gal сар.

(DOT-11A, 11B) WIC not over 16 gal. cap.

Wooden boxes, WIO (DOT-15A, 15B, 150, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIC:

(DOT-12A, 12B) not over 65 lb. gr. wt.

(DOT-12E) WIMC not over 110 lb. gr. wt.

Fiber or plywood drums (DOT210, 22A, 22B) WIC not over 1 gal. cap.

Fiber drum (DOT-21P) WIO DOT-28, DOT-28 L, not over 55 gal, cap.

Cylinders as prescribed for any compressed gas except acety. lene.

Authorized only for export ship

ments:

Steel barrels or drums (DOT17X) STC, not over 55 gal. cap.

Wooden boxes, WIMC (DOT15X) not over 10 gal. cap.

[blocks in formation]

Table D-Classification:

Required conditions for transportation

Stowage:

Cargo vessel

"On deck protected." "On deck under cover.' Outside containers:

Steel barrels or drums.

(DOT-5, 5A, 5B, 5C, 5G) not over 110 gal. cap.

(DOT-5M) not over 55 gal. cap. (DOT-170) STC, not over 55 gal. cap.

(DOT-17E) STC, not over 55 gal. cap.

(DOT-17H, 37A) WIC of glass,
not over 9 pts. cap. each.
Cylindrical steel overpack:
(DOT-6D) WIC DOT-28, not
over 55 gal. cap.

Aluminum barrels or drums:
(DOT-42B, 42C, 42H) not over
55 gal cap.

Wooden barrels or kegs:

(DOT-10A) not over 50 gal. сар.

(DOT-11A, 11B) WIC not over 16 gal. cap.

Wooden boxes, WIC (DOT-15A, 15B, 15C, 16A, 19A, 19B) not over 10 gal. total cap. Fiberboard boxes, WIC (DOT12A, 12B) not over 65 lb. gr. wt. Fiber or plywood drums (DOT21C, 22A, 22B) WIC not over 1 gal. cap.

Fiber drum (DOT-21P) WIC DOT-2S, DOT-28L, not over 55 gal. cap.

Cylinders as prescribed for any compressed gas except acetylene.

Authorized for stowage "On

deck in open" only:

Portable tanks (DOT-51) not over 20,000 lb. gr. wt.

Authorized for stowage "On deck" and "First deck below":

Motor vehicle tank trucks complying with DOT regulations (trailerships and trainships only).

Tank cars complying with DOT regulations (trainships only).

[blocks in formation]