Code of Federal Regulations: Containing a Codification of Documents of General Applicability and Future Effect as of December 31, 1948, with Ancillaries and IndexDivision of the Federal Register, the National Archives, 2000 - Administrative law |
From inside the book
Results 1-5 of 29
Page 43
... step must be long enough so that the distance between the center of the lashing ring and the top of the first step is approximately 600 mm ( 24 in . ) . ( c ) Lashing rings . A lashing ring must be securely attached to the top and ...
... step must be long enough so that the distance between the center of the lashing ring and the top of the first step is approximately 600 mm ( 24 in . ) . ( c ) Lashing rings . A lashing ring must be securely attached to the top and ...
Page 44
... step . This test is performed on six dif- ferent steps . No step may break , crack , or incur any deformation that remains after the static load is removed . No at- tachment between any step and a sus- pension member may loosen or break ...
... step . This test is performed on six dif- ferent steps . No step may break , crack , or incur any deformation that remains after the static load is removed . No at- tachment between any step and a sus- pension member may loosen or break ...
Page 194
... steps necessary to make a PFD provide its intended flotation characteristics after the device has been properly donned and then in- flated . ( 1 ) SOLAS lifejacket , in the case of a hybrid inflatable PFD , means a PFD approved as ...
... steps necessary to make a PFD provide its intended flotation characteristics after the device has been properly donned and then in- flated . ( 1 ) SOLAS lifejacket , in the case of a hybrid inflatable PFD , means a PFD approved as ...
Page 217
... steps of each boarding lad- der must provide a suitable foothold . ( n ) Canopy lamps ( Regulation III / 39.6.2 ) . The exterior liferaft canopy lamp must be approved by the Com- mandant under approval series 161.101 . ( 0 ) Containers ...
... steps of each boarding lad- der must provide a suitable foothold . ( n ) Canopy lamps ( Regulation III / 39.6.2 ) . The exterior liferaft canopy lamp must be approved by the Com- mandant under approval series 161.101 . ( 0 ) Containers ...
Page 247
... step ( 3 ) of the final cycle of cold storage , two test subjects who success- fully completed the donning test pre- viously enter the cold chamber , unpack and don the thermal protective aids . The aids must not show any damage , such ...
... step ( 3 ) of the final cycle of cold storage , two test subjects who success- fully completed the donning test pre- viously enter the cold chamber , unpack and don the thermal protective aids . The aids must not show any damage , such ...
Other editions - View all
Common terms and phrases
accepted amended by CGD applicable approval tests ASTM boat body strap buoy buoyant apparatus buoyant vests CGFR chapter Coast Guard approval color Commandant components conducted construction container davits device equipment facturer Federal Register fire float foam hybrid PFD ignite immersion suit inches Incorporation by reference independent laboratory inflatable liferaft inflation mechanism inspec inspections and tests inspector kapok ladder least less lifeboat lifejacket listing and labeling load lock stitch mandant manual manufac manufacturer manufacturer's marine marked meet the requirements ments monitor oil content percent performance Personal Flotation Devices PFD's pounds Procedure for approval production tests proval quired quirements ratus recognized laboratory rejected lot Reserved retroreflective rial sample seam Sept specimen Standard stitching submerged subpart suit surface tank temperature Test Method tested in accordance tests required thermocouple thickness tion Type U.S. Coast Guard Underwriters Laboratories valves vessel wearer weight workmanship
Popular passages
Page 400 - V National Highway Traffic Safety Administration, Department of Transportation (Parts 500—599) VI Federal Transit Administration, Department of Transportation (Parts 600—699) VII National Railroad Passenger Corporation (AMTRAK) (Parts 700—799...
Page 333 - ... of this section. (3) The standard time-temperature curve is defined by a smooth curve drawn through the following points: At the beginning of the test. 20 °C. (68 °F.) At the end of the first 5 minutes, 538 °C.
Page 4 - CFR part 51. To enforce any edition other than that specified in Paragraph (b) of this section, the Coast Guard must publish notice of change in the FEDERAL REGISTER; and the material must be available to the public.
Page 37 - A minimum factor of safety of six on the ultimate strength of the material shall be maintained at all times based on the approved working load. (b) Worm gears, spur gears, or a combination of both, may be used in the construction of lifeboat winches. All gears shall be machine cut and made of steel, bronze, or other suitable material properly keyed to shafts. The use of cast iron is not permitted for these parts. (c) Screws, nuts, bolts, pins, keys, etc., securing moving parts shall be fitted with...
Page 403 - Index List of Agency Prepared Indexes Parallel Tables of Statutory Authorities and Rules List of CFR Titles, Chapters, Subchapters, and Parts Alphabetical List of Agencies Appearing in the CFR Alphabetical List of Agencies Appearing in the CFR...
Page 396 - PROVISIONS RELATING TO PUBLIC CONTRACTS 50 Public Contracts, Department of Labor (Parts 50-1—50-999) 51 Committee for Purchase From People Who Are Blind or Severely Disabled (Parts 51-1—51-99) 60 Office of Federal Contract Compliance Programs, Equal Employment Opportunity, Department of Labor (Parts 60-1—60-999) 61 Office of the Assistant Secretary for Veterans...
Page 285 - DC, 20226. (b) Drawings and specifications. Manufacturers desiring approval of a new design or type of pressure-vacuum relief valve and spill valve shall submit drawings in quadruplicate showing the design of the valve, the sizes for which approval is requested, method of operation, thickness and material specifications of component parts, diameter of seat opening and lift of discs, mesh and size of wire of flame screens. (c) Pre-approval tests. Before approval is granted, the manufacturer shall...
Page 125 - Any examinations, inspections and tests which are required by the recognized laboratory for listed and labeled devices produced will be conducted by the laboratory inspector at the place of manufacture or other location at the option of the laboratory.
Page 388 - Office of Transportation, Department of Agriculture (Parts 3300—3399) XXXIV Cooperative State Research, .Education, and Extension Service. Department of Agriculture (Parts 3400—3499) XXXV Rural Housing Service, Department of Agriculture (Parts 3500— 3599...
Page 337 - ... as possible. The thermocouples shall be arranged so that the hot junction is approximately 10 cm. (4") from the nearest point of the specimen. (2) The furnace temperature shall be continuously controlled so as to follow the standard time-temperature curve within the accuracy specified in paragraph (c)(4) of this section. (3) The standard time-temperature curve is defined by a smooth curve drawn through the following points: At the beginning of the test, 20° C. (68° F.).