Page images
PDF
EPUB
[blocks in formation]

aesthetics.

5. PROJECT NUMBER
H-1-97-1

The lack of landscaping results in poor drainage, erosion, lack of privacy and community aesthetics.

IMPACT IF NOT PROVIDED: construction standards. unacceptably high.

These units will continue to fall short of DOD new
Operation and maintenance costs will continue to be

JOINT USE CERTIFICATION: The Deputy Chief of Naval Operations (Logistics) certifies that this project has been considered for joint use potential. facility will be available for use by other components.

This

[blocks in formation]

1. COMPONENT FY 2003 MILITARY CONSTRUCTION PROJECT DATA 2. DATE

NAVY

[blocks in formation]

04/06/01

QTRS F-33W, REPLACE GARAGE AND REFINISH
WINDOWS

[blocks in formation]

This project encompasses improvements that will provide for the demolition of the existing one-car garage by replacing it with a two-car garage. Major repairs will include refinishing and adjusting windows throughout the unit. Quarters F-33W is a single- family residence which was constructed in 1907. This home is listed on the National Register of Historic Places and the Virginia State Historical Society Register. Construction must comply with the Secretary of the Interior's Standards for the Rehabilitation of Historic Buildings. Lead paint and asbestos will be addressed.

11. REQUIREMENT

PROJECT: Flag Quarters F-33W is located at the Norfolk Naval Station, Norfolk, Virginia. It is a single-family residence, located at 1655 Dillingham Blvd. The "Ohio House-West" was constructed in 1907 and contains 5,469 gross square feet. This project includes refinishing and adjusting all windows. Improvements include demolition of the existing one-car garage and replacement with a new two-car garage.

REQUIREMENT: Provide adequate family housing unit for flag and general officer and family members in conformance with applicable codes and criteria. Fix windows that are painted shut, leak air, are missing hardware, have damaged sash and peeling paint. The garage project includes all required demolition, design, construction, site-work, grading and landscaping.

[merged small][merged small][merged small][ocr errors][merged small][merged small]
[blocks in formation]

CURRENT SITUATION:

Every window in the house needs to be refinished and adjusted; some leak, some are painted shut and most are missing hardware. The existing garage has termite damage to the side and back walls and the roof needs to be replaced. The interior/exterior paint is peeling, single-pane sash windows are deteriorated.

IMPACT IF NOT PROVIDED: Failure to replace the existing garage will accelerate the overall deterioration of the home and result in the continuing rise in maintenance and repair costs. Eventually the structure will be deemed unsuitable for use which will cause a hardship for residents due to lack of storage and convenience. Further delays to restore the windows in this unit will lead to unacceptable standards of living with respect to energy efficiency and convenience and will impact the quality of life of the residents.

JOINT USE CERTIFICATION: The Deputy Chief of Naval Operations (Logistics) certifies that this project has been considered for joint use potential. facility will be available for use by other components.

DD

FORM
1 DEC 76

1391c

PREVIOUS EDITIONS MAY BE USED
INTERNALLY UNTIL EXHAUSTED

PAGE NO

This

[blocks in formation]

This project provides for major repairs and improvements to the garage and driveway to include: demolition of the existing one-car garage by replacement with a two-car garage; replacement of existing driveway, and

repair/replacement of storm drains associated with the garage improvements; and site-work, grading and landscaping. Lead paint and asbestos will be addressed. This home is listed on the National Register of Historic Places. Design and construction will be in accordance with the provisions of applicable laws on Historic Preservation.

11. REQUIREMENT

PROJECT: This project provides for improvements and repairs to one Flag
unit, Quarters G-8, located on Naval Station Norfolk, Norfolk, Virginia.
It is a single-family residence, located at 1610 Powhatan Street. The
"Illinois House" was constructed in 1907, contains 5,990 gross square
feet and has five bedrooms, two full baths, one 3/4 bath and one half
bath.

REQUIREMENT: This project is required to replace the existing garage that has been condemned due to major deterioration and termite infestation.

CURRENT SITUATION: The existing garage has termite damage and has deteriorated beyond its normal life expectancy. Replacement of the driveway and repair/replacement of storm drains should be completed in conjunction for cost efficiency within this improvement project.

DD

FORM
1 DEC 76

1391

PREVIOUS EDITIONS MAY BE USED
INTERNALLY UNTIL EXHAUSTED

PAGE NO

[blocks in formation]

IMPACT IF NOT PROVIDED: The existing garage is a dilapidated structure that poses an eyesore in the historic district. Failure to replace the existing garage will lead to structural failure, safety hazards and damage to

surrounding property.

JOINT USE CERTIFICATION: The Deputy Chief of Naval Operations (Logistics) certifies that this project has been considered for joint use potential. facility will be available for use by other components.

This

[blocks in formation]
« PreviousContinue »