Page 127
... capacity of the entire scaffold shall be reduced accordingly . The width of a sectional folding stairway scaffold shall not exceed 41⁄2 feet . The maximum length of a sectional folding stairway scaffold shall not exceed 6 feet . ( 5 ) ...
... capacity of the entire scaffold shall be reduced accordingly . The width of a sectional folding stairway scaffold shall not exceed 41⁄2 feet . The maximum length of a sectional folding stairway scaffold shall not exceed 6 feet . ( 5 ) ...
Page 129
... capacity appro- priate to the individual building or structure , with due regard to the char- acter of the occupancy , the number of persons exposed , the fire protection available , and the height and type of construction of the ...
... capacity appro- priate to the individual building or structure , with due regard to the char- acter of the occupancy , the number of persons exposed , the fire protection available , and the height and type of construction of the ...
Page 131
... capacity in number of persons per unit of exit width for ap- proved components of means of egress shall be as ... capacity and occupant load . ( 1 ) The capacity of means of egress for any floor , balcony , tier , or other occu- pied ...
... capacity in number of persons per unit of exit width for ap- proved components of means of egress shall be as ... capacity and occupant load . ( 1 ) The capacity of means of egress for any floor , balcony , tier , or other occu- pied ...
Page 144
... capacity of the hoist . ( A ) The primary brake shall be di- rectly connected to the drive train of the hoisting machine , and shall not be connected belts , through chains , clutches , or set screw type devices . The brake shall ...
... capacity of the hoist . ( A ) The primary brake shall be di- rectly connected to the drive train of the hoisting machine , and shall not be connected belts , through chains , clutches , or set screw type devices . The brake shall ...
Page 197
... capacity to produce the flow of air re- quired in each of the hoods and open- ings of the system . ( ii ) The capacity required in subdivi- sion ( i ) of this subparagraph shall be obtained when the airflow producing equipment is ...
... capacity to produce the flow of air re- quired in each of the hoods and open- ings of the system . ( ii ) The capacity required in subdivi- sion ( i ) of this subparagraph shall be obtained when the airflow producing equipment is ...
Other editions - View all
Common terms and phrases
ammonium nitrate ANSI ANSI/NFPA appendix applicable Assistant Secretary audiogram Bitrex brake building chemical combustible comply construction container crane designed device diameter discharge electrical employees entry equipment evaluation explosives exposure extinguishers fall arrest feet fit test flammable floor graph guard hazards hoisting horizontal hose IBR approved IDLH inches inspection installed ladder least less liquid load located machine material maximum means ment metal minimum National NFPA opening operations OSHA paragraph performed permit space person personal protective equipment piping platform ployer portable pressure prevent procedures process safety management PSDI reference as specified relief valves requirements respirator rim wheel safe safety and health safety relief scaffold self-contained breathing apparatus sensing field slings spray standard storage subpart tainer tank tion trucks valve vapor vent ventilation vertical vided welding wheel wire rope workplace