... inches ) , when the vessel is at a forward pitch angle of 20 degrees . ( c ) Polarized or tinted windows must not be fitted . [ CGD 85-099 , 55 FR 32248 , Aug. 8 , 1990 ] Subpart 92.05 - General Fire Protection § 92.05-1 Fire hazards to ...
... inches ) , when the vessel is at a forward pitch angle of 20 degrees . ( c ) Polarized or tinted windows must not be fitted . [ CGD 85-099 , 55 FR 32248 , Aug. 8 , 1990 ] Subpart 92.05 - General Fire Protection § 92.05-1 Fire hazards to ...
Page 39
... inch . ( 7 ) Ceilings , linings , and insulation , including pipe and duct laggings , shall be of approved incombustible mate- rials . ( 8 ) Any sheathing , furring or holding pieces incidental to the securing of any bulkhead , ceiling ...
... inch . ( 7 ) Ceilings , linings , and insulation , including pipe and duct laggings , shall be of approved incombustible mate- rials . ( 8 ) Any sheathing , furring or holding pieces incidental to the securing of any bulkhead , ceiling ...
Page 40
... inches . The angle of inclina- tion with the horizontal of such stair- ways shall not exceed 50 degrees . § 92.10-30 Dead end corridors . ( a ) Dead end corridors , or the equiva- lent , more than 40 feet in length shall not be ...
... inches . The angle of inclina- tion with the horizontal of such stair- ways shall not exceed 50 degrees . § 92.10-30 Dead end corridors . ( a ) Dead end corridors , or the equiva- lent , more than 40 feet in length shall not be ...
Page 42
... inches ) wide by 190 centi- meters ( 75 inches ) long , except by spe- cial permission of the Commandant . Where 2 tiers of berths are fitted , the bottom of the lower berth must not be less than 30 centimeters ( 12 inches ) above the ...
... inches ) wide by 190 centi- meters ( 75 inches ) long , except by spe- cial permission of the Commandant . Where 2 tiers of berths are fitted , the bottom of the lower berth must not be less than 30 centimeters ( 12 inches ) above the ...
Page 44
... inches . The courses shall not be more than 15 inches apart . In the case of ships with rounded gunwales the guard rail supports shall be placed on the flat of the deck . On other decks and bridges the rails shall be in at least two ...
... inches . The courses shall not be more than 15 inches apart . In the case of ships with rounded gunwales the guard rail supports shall be placed on the flat of the deck . On other decks and bridges the rails shall be in at least two ...
Other editions - View all
Common terms and phrases
accommodation space alarm system amended at 62 amended by CGD appliance applicable approved arrangement battery bulkhead cable carbon dioxide cargo tanks carrying Certificate of Inspection CGFR chapter circuit breaker Coast Guard cognizant OCMI combustible Commandant condition conductor construction crew deck device door drydock emergency power source engine feet fire extinguishing fire main firehose fitted flammable foam gross tons hose hull immersion suits inches inspec installed June launching least lifeboat liferaft lifesaving liquid load machinery space Marine Inspection material means meet the requirements ment meters millimeters motor navigating bridge November 19 Officer in Charge operation overcurrent paragraph passengers person in charge piping portable tank pressure propulsion protected quired quirements rescue boat safety Sept ship's service standard station stowage subchapter Subpart survival craft switch switchboard tion U.S. Coast Guard USCG valves ventilation vessel watertight