Code of Federal RegulationsU.S. General Services Administration, National Archives and Records Service, Office of the Federal Register, 2003 - Administrative law |
From inside the book
Results 1-5 of 100
Page 16
... - propelled vehicles with batteries connected and fuel tanks containing gasoline on ves- sels on ocean or unlimited coastwise voyages . Requirements for the design and protection of spaces 16 ยง 90.10-25 46 CFR Ch . 1 ( 10-1-05 Edition )
... - propelled vehicles with batteries connected and fuel tanks containing gasoline on ves- sels on ocean or unlimited coastwise voyages . Requirements for the design and protection of spaces 16 ยง 90.10-25 46 CFR Ch . 1 ( 10-1-05 Edition )
Page 24
... connection with cargo gear certification must have all required entries fully com- pleted as of the dates indicated , shall be kept current , and shall include the following : ( 1 ) A register of the cargo handling machinery and the ...
... connection with cargo gear certification must have all required entries fully com- pleted as of the dates indicated , shall be kept current , and shall include the following : ( 1 ) A register of the cargo handling machinery and the ...
Page 48
... connection to an oil line be used as a fire pump . Branch lines connected to the fire main for purposes other than fire and deck wash shall be so arranged that ade- quate water can be made continuously available for firefighting ...
... connection to an oil line be used as a fire pump . Branch lines connected to the fire main for purposes other than fire and deck wash shall be so arranged that ade- quate water can be made continuously available for firefighting ...
Page 49
... connection to the fire main available to each side of the vessel in an acces- or sible location . Suitable cut - out ... connected to the outlets at all times . However , on open decks where no protection is af- forded to the hose in ...
... connection to the fire main available to each side of the vessel in an acces- or sible location . Suitable cut - out ... connected to the outlets at all times . However , on open decks where no protection is af- forded to the hose in ...
Page 54
... connected , a pressure test shall be ap- plied as set forth in this paragraph . Only carbon dioxide or other inert gas shall be used for this test . ( 2 ) The piping from the cylinders to the stop valves in the manifold shall be ...
... connected , a pressure test shall be ap- plied as set forth in this paragraph . Only carbon dioxide or other inert gas shall be used for this test . ( 2 ) The piping from the cylinders to the stop valves in the manifold shall be ...
Other editions - View all
Common terms and phrases
accommodation space alarm system amended at 62 amended by CGD appliance applicable approved arrangement battery bulkhead cable carbon dioxide cargo tanks carrying Certificate of Inspection CGFR chapter circuit breaker Coast Guard cognizant OCMI combustible Commandant condition conductor construction crew deck device door drydock emergency power source engine feet fire extinguishing fire main firehose fitted flammable foam gross tons hose hull immersion suits inches inspec installed June launching least lifeboat liferaft lifesaving liquid load machinery space Marine Inspection material means meet the requirements ment meters millimeters motor navigating bridge November 19 Officer in Charge operation overcurrent paragraph passengers person in charge piping portable tank pressure propulsion protected quired quirements rescue boat safety Sept ship's service standard station stowage subchapter Subpart survival craft switch switchboard tion U.S. Coast Guard USCG valves ventilation vessel watertight