" A" Class shall be composed of steel or equivalent metal construction, suitably stiffened and made intact with the main structure of the vessel; such as shell, structural bulkheads, and decks. They shall be so constructed, that if subjected to the standard... "
Code of Federal Regulations: 2000- - Page 34
2000
Full view - About this book

The Code of Federal Regulations of the United States of America ..., Book 5

Administrative law - 1948 - 1480 pages
...mean length of which shall not exceed 131 feet. (c) All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15. B-0, or C, depending upon the...they would be capable of preventing the passage of flame for one hour. In addition, they shall be so insulated with approved structural Insulation, bulkhead...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 1985 - 416 pages
...10 minutes— 1,300° F. 30 minutes— 1,550° F. 60 minutes— 1,700° F. (b) "A" Class divisions. Bulkheads or decks of the "A" Class shall be composed...they would be capable of preventing the passage of flame and smoke for one hour. (c) "B" Class bulkheads. Bulkheads of the "B" Class shall be constructed...
Full view - About this book

The Code of Federal Regulations of the United States of America

Administrative law - 1988 - 422 pages
...10 minutes— 1,300° F. 30 minutes— 1,550° F. 60 minutes — 1,700° F. (b) "A" doss divisions. Bulkheads or decks of the "A" Class shall be composed...they would be capable of preventing the passage of flame and smoke for one hour. (c) "B" Class bulkheads. Bulkheads of the "B" Class shall be constructed...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 1953 - 1392 pages
...by the Commandant. (c) All bulkheads and decks shall be classed as A-60, A-30. A-15, AO. B-15. BO, or C, depending upon the type of space on each side...vessel, such as shell structural bulkheads, and decks. The? shall be so constructed that, if subjected to the standard fire test, they would be capable of...
Full view - About this book

The Code of Federal Regulations of the United States of America

Administrative law - 1974 - 188 pages
...10 minutes — 1,300' P. 30 minutes — 1,660' P. 60 minutes— 1,700' P. (b) "A" Class divisions. Bulkheads or decks of the "A" Class shall be composed...bulkheads, and decks. They shall be so constructed, that If sub§ 92.07-10 Jected to the standard fire test, they •would be capable of preventing the passage...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 1979 - 370 pages
...10 minutes— 1,300° F. 30 minutes— 1,550° F. 60 minutes— 1,700° F. (b) "A" Class divisions. Bulkheads or decks of the "A" Class shall be composed...the vessel; such as shell, structural bulkheads, and Jecks. They shall be so constructed, that if subjected to the standard fire test, they would be capable...
Full view - About this book

The Code of Federal Regulations of the United States of America

Administrative law - 1970 - 588 pages
...approved incombustible materials and made intact from deck to deck and to shell or other boundaries. They shall be so constructed that, if subjected to...they would be capable of preventing the passage of flame and smoke for one-half hour. (d) "C" Class divisions. Bulkheads or decks of the "C" Class shall...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 2000 - 572 pages
...noncombustible materials. (vi) C'-Class bulkheads and decks must be constructed of noncombustible materials and made intact with the main structure of the vessel, such as shell, structural bulkheads, and decks, except that a C'-Class bulkhead need not extend above a continuous B-Class or C'-Class ceiling. C'-Class...
Full view - About this book

The Code of Federal Regulations of the United States of America

Administrative law - 1970 - 626 pages
...approved incombustible materials and made intact from deck to deck and to shell or other boundaries. They shall be so constructed that, if subjected to the standard fire test, they would be capable oí preventing the passage of flame and smoke for one half hour. (d) "C" Class divisions. Bulkheads...
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

Administrative law - 1975 - 222 pages
...made intact from deck to deck and to shell or other boundaries. They shall be so constructed that. It subjected to the standard fire test, they would be capable of preventing the passage of flame and smoke for one half hour. (d) "C" Class divisions. Bulkheads or decks of the "C" Class shall...
Full view - About this book