Page 8
... maximum hourly average concentra- tions above 0.12 parts per million ( 235 μg / m3 ) is equal to or less than 1 , as de- termined by appendix H to this part . ( b ) The 1 - hour standards set forth in this section will remain applicable ...
... maximum hourly average concentra- tions above 0.12 parts per million ( 235 μg / m3 ) is equal to or less than 1 , as de- termined by appendix H to this part . ( b ) The 1 - hour standards set forth in this section will remain applicable ...
Page 9
... maximum arithmetic mean averaged over a calendar quarter . ( Secs . 109 , 301 ( a ) Clean Air Act as amended ( 42 U.S.C. 7409 , 7601 ( a ) ) ) [ 43 FR 46258 , Oct. 5 , 1978 ] APPENDIX A TO PART 50 - REFERENCE METHOD FOR THE ...
... maximum arithmetic mean averaged over a calendar quarter . ( Secs . 109 , 301 ( a ) Clean Air Act as amended ( 42 U.S.C. 7409 , 7601 ( a ) ) ) [ 43 FR 46258 , Oct. 5 , 1978 ] APPENDIX A TO PART 50 - REFERENCE METHOD FOR THE ...
Page 15
... maximum absorbance at a wavelength of 540 nm when assayed in a buffered solution of 0.1 M sodium ace- tate - acetic acid ; • The absorbance of the reagent blank , which is temperature sensitive ( 0.015 ab- sorbance unit / ° C ) , must ...
... maximum absorbance at a wavelength of 540 nm when assayed in a buffered solution of 0.1 M sodium ace- tate - acetic acid ; • The absorbance of the reagent blank , which is temperature sensitive ( 0.015 ab- sorbance unit / ° C ) , must ...
Page 26
... maximum weight loss . ( 11 ) 7.1.8 Pinholes : None . 7.1.9 Tear strength : 500 g minimum for 20 mm wide strip cut from filter in weakest di- mension . ( See ASTM Test D828-60 ) . 7.1.10 Brittleness : No cracks or material sep- arations ...
... maximum weight loss . ( 11 ) 7.1.8 Pinholes : None . 7.1.9 Tear strength : 500 g minimum for 20 mm wide strip cut from filter in weakest di- mension . ( See ASTM Test D828-60 ) . 7.1.10 Brittleness : No cracks or material sep- arations ...
Page 30
... maximum con- trol range . The sample flow rate should be verified at this time with a clean filter in- stalled . Then add two or more filters to the sampler to see if the flow controller main- tains a constant flow ; this is ...
... maximum con- trol range . The sample flow rate should be verified at this time with a clean filter in- stalled . Then add two or more filters to the sampler to see if the flow controller main- tains a constant flow ; this is ...
Other editions - View all
Common terms and phrases
actual emissions adjustment air pollution air quality air quality standards ambient air quality amount appendix applicable approved arithmetic mean average calculated calibration chapter Clean Air Act Clean Unit designation cogeneration compliance comply concentration control measures control technology determined device emis emission factor emission limitation emissions data emissions increase emissions reductions emissions trading emissions trading program emissions unit enforceable Federal filter flow rate fuel graph implementation plan inventory major modification major stationary source maximum ments monitoring nitrogen dioxide NO₂ non-EGUS nonattainment nonroad NOx Budget NOx emissions number of exceedances owner or operator ozone season PAL permit PAL pollutant particulate matter percent PLCS procedures pursuant quirements reporting requirements of paragraph reviewing authority sample period sampler sions unit SIP revision specified stack State's submit subpart sulfur dioxide temperature throughput tion tons unit's vehicle volumetric flask µg/m³