NO2 concentrations in the range required . Ozone generators of the electric discharge type may produce NO and NO2 and are not recommended . 1.2.7 Valve . A valve may be used as shown in Figure 1 to divert the NO flow when zero air is ...
NO2 concentrations in the range required . Ozone generators of the electric discharge type may produce NO and NO2 and are not recommended . 1.2.7 Valve . A valve may be used as shown in Figure 1 to divert the NO flow when zero air is ...
Page 75
... electrical , or electronic control capability to meet or exceed the design and functional performance as specified in this section 7.0 of this appendix . The performance specifications require that the sampler : ( a ) Provide automatic ...
... electrical , or electronic control capability to meet or exceed the design and functional performance as specified in this section 7.0 of this appendix . The performance specifications require that the sampler : ( a ) Provide automatic ...
Page 78
... electrical power , under sec- tion 7.4.13 of this appendix , or flow rate cut off , under section 7.4.4 of this appendix . ( c ) These parameters shall be accessible to the sampler operator as specified in table L- 1 of section 7.4.19 ...
... electrical power , under sec- tion 7.4.13 of this appendix , or flow rate cut off , under section 7.4.4 of this appendix . ( c ) These parameters shall be accessible to the sampler operator as specified in table L- 1 of section 7.4.19 ...
Page 80
... electrical power interruption . 7.4.13 Sample time determination . The sam- pler shall be capable of determining the elapsed sample collection time for each PM2.5 sample , accurate to within ± 1.0 minute , measured as the time between ...
... electrical power interruption . 7.4.13 Sample time determination . The sam- pler shall be capable of determining the elapsed sample collection time for each PM2.5 sample , accurate to within ± 1.0 minute , measured as the time between ...
Page 81
... Electrical Code and Underwriters Lab- oratories electrical safety requirements . 7.4.15.3 The design of all electrical and electronic controls shall be such as to pro- vide reasonable resistance to interference or malfunction from ...
... Electrical Code and Underwriters Lab- oratories electrical safety requirements . 7.4.15.3 The design of all electrical and electronic controls shall be such as to pro- vide reasonable resistance to interference or malfunction from ...
Other editions - View all
Common terms and phrases
actual emissions adjustment air pollution air quality air quality standards ambient air quality amount appendix applicable approved arithmetic mean average calculated calibration chapter Clean Air Act Clean Unit designation cogeneration compliance comply concentration control measures control technology determined device emis emission factor emission limitation emissions data emissions increase emissions reductions emissions trading emissions trading program emissions unit enforceable Federal filter flow rate fuel graph implementation plan inventory major modification major stationary source maximum ments monitoring nitrogen dioxide NO₂ non-EGUS nonattainment nonroad NOx Budget NOx emissions number of exceedances owner or operator ozone season PAL permit PAL pollutant particulate matter percent PLCS procedures pursuant quirements reporting requirements of paragraph reviewing authority sample period sampler sions unit SIP revision specified stack State's submit subpart sulfur dioxide temperature throughput tion tons unit's vehicle volumetric flask µg/m³