... device to prevent entrained liq- uid from reaching the flow control device . The tube is packed with indicating silica gel as shown in Figure 2. Glass wool may be sub- stituted for silica gel when collecting short- term samples ( 1 hour ...
... device to prevent entrained liq- uid from reaching the flow control device . The tube is packed with indicating silica gel as shown in Figure 2. Glass wool may be sub- stituted for silica gel when collecting short- term samples ( 1 hour ...
Page 12
... A MIDGET IMPINGER IS USED FOR 1 HOUR SAMPLING . TRAP Figure 2. 24 - Hour sampling system . VACUUM GAUGE VACUUM PUMP 7.1.6 Flow control device : A calibrated ro- tameter and. 12 Pt . 50 , App . A 40 CFR Ch . I ( 7-1-05 Edition )
... A MIDGET IMPINGER IS USED FOR 1 HOUR SAMPLING . TRAP Figure 2. 24 - Hour sampling system . VACUUM GAUGE VACUUM PUMP 7.1.6 Flow control device : A calibrated ro- tameter and. 12 Pt . 50 , App . A 40 CFR Ch . I ( 7-1-05 Edition )
Page 13
... device : Device cali- brated as specified in 9.4.1 and used to meas- ure sample flow rate at the monitoring site . 7.1.8 Membrane particle filter : A membrane filter of 0.8 to 2 μm porosity is used to pro- tect the flow controller from ...
... device : Device cali- brated as specified in 9.4.1 and used to meas- ure sample flow rate at the monitoring site . 7.1.8 Membrane particle filter : A membrane filter of 0.8 to 2 μm porosity is used to pro- tect the flow controller from ...
Page 17
... device connected to the inlet of the absorber . For 24 - hour samples , the standard flow rate is determined at the time the absorber is placed in the sampling train and again when the absorber is removed from the train for shipment to ...
... device connected to the inlet of the absorber . For 24 - hour samples , the standard flow rate is determined at the time the absorber is placed in the sampling train and again when the absorber is removed from the train for shipment to ...
Page 19
... device is held constant ( 10.1 ° C ) and the device has been accurately calibrated at the temperature of use . The SO2 permeating from the device is carried by a low flow of dry carrier gas to a mixing chamber where it is diluted with ...
... device is held constant ( 10.1 ° C ) and the device has been accurately calibrated at the temperature of use . The SO2 permeating from the device is carried by a low flow of dry carrier gas to a mixing chamber where it is diluted with ...
Other editions - View all
Common terms and phrases
actual emissions adjustment air pollution air quality air quality standards ambient air quality amount appendix applicable approved arithmetic mean average calculated calibration chapter Clean Air Act Clean Unit designation cogeneration compliance comply concentration control measures control technology determined device emis emission factor emission limitation emissions data emissions increase emissions reductions emissions trading emissions trading program emissions unit enforceable Federal filter flow rate fuel graph implementation plan inventory major modification major stationary source maximum ments monitoring nitrogen dioxide NO₂ non-EGUS nonattainment nonroad NOx Budget NOx emissions number of exceedances owner or operator ozone season PAL permit PAL pollutant particulate matter percent PLCS procedures pursuant quirements reporting requirements of paragraph reviewing authority sample period sampler sions unit SIP revision specified stack State's submit subpart sulfur dioxide temperature throughput tion tons unit's vehicle volumetric flask µg/m³